Worldwide  |  About Us  |  Contact  |  Login 


Triton Home Page Dover Corporation

 

Dispenser Mechanisms

MiniMech™ TDM 250 SDD NMD 50 Fujitsu 510 NMD 100


 De LA Rue
MiniMech™




Specifications

Media capability - thickness ranges -
 Width: 60 to 82mm, Length: 110 to 180mm,
Thickness: 0.06 to 0.18mm

Maximum note tray capacity -
A note pile of 110mm or up to 1000 banknotes

Weight - Mechanism -
(without tray and notes) : 5.3kg (11.7lbs)

Note tray with reject compartment:
(without notes) : 1.6kg (3.5lbs)




Communication interface-
RS232C connection as provided standard

Power supply requirements -
DC-only supply 24V ± 10%
Max  load current 2.5A

Operating environment -
Temperature : 10 to 50°C, 50 to 122°F
 Relative humidity : 10 to 90% non-condensing

TDM 250



Specifications

Delivery Rate : 2.5 notes per second
Cassettes: 2

Cassette capacity -
1200 used notes per cassette

Reject box capacity:
100 used notes

Life:
250,000 notes

Access:
Rear
  Height: 18.155 in
  Width: 13.155 in
  Length: 9.6 in
  Weight: 16 lbs (7.26 kg)

Voltage input -
+12 VDC and +24 VDC (+/-5%)

Interface: RS232

Operating Environment-
Temperature : 10°- 40° C (50°-104° F)

Relative humidity: 20% to 80% non-condensing

Maximum/minimum media height -
95.6mm   (3.76 in) / 59mm (2.32 in)
Maximum/minimum media width -
172.9 mm   (6.8 in) / 112 mm (4.41 in)

De LA Rue
SDD 1700



Specifications

Media capability - thickness ranges -   
Width: 57mm to 98mm, Length: 110mm to 192mm, Thickness: 0.07 to 0.15mm

Maximum cassette capacity -
Standard options: a note pile of 260mm or 1650 to 2150 banknotes
Short options: a note pile of 117mm or 700 to 900 banknotes

Loading frame-
The loading frame must be used to open the cassette and also ensures correct loading of documents

Weight (without notes) -
1700 Front service, standard SDD : 8.5kg (18.7lbs)

Communication interface -
RS232C, RS485, TTL serial interface with polling or handshake control, standard

Power supply requirements -
DC-only supply - power levels :
   ° 5V DC ± 0.2V – Max load current 1.5A
   ° 36V DC ± 2V average – Max load
      current 5A

Operating environment-
Temperature: 5 to 50°C, 41 to 122°F
Relative humidity: 10 to 90% non-condensing

De LA Rue
NMD 50



Specifications

Media capability -
 Width: 58 to 85mm
Length:100 to 181mm
Thickness: 0.06 to 0.18mm

Maximum cassette capacity-
Short cassette:
240mm or up to 2000 banknotes
Long cassette:
340mm or up to 3000 banknotes

Weight (without notes) -
Standard 1-denomination NMD 50 (with cassette): 16.4kg (36.2lbs)

Communication interface -
RS232C connection as standard

Power supply requirements-
DC-only supply -power levels :
° +12V ± 10% Max load current 3A
° +36V ± 10% Max load current 5A

Operating environment -
Temperature : 5 to 50°C, 41 to 122°F
Relative humidity : 10 to 90% non-condensing

Fujitsu 510

510
Specifications

Media capability -
The 510 will handle the following size and thickness ranges:

Width- 60 to 120mm • Length: 82 to 172mm

Thickness- 0.07 to 0.18mm

Maximum note tray capacity: (dependent on thickness and quality) • A note pile of 370mm or up to 3000 US new banknotes


Weight-
Mechanism (5 cassettes without notes): 62kg

Communication interface-
RS232C connection as provided standard

Power supply requirements-

The mechanism operates from a DC-only supply and • requires the following power level • 24V ± 10% – Max load current 10A

• Operating environment
-
Temperature: 0 to 32°C
Relative humidity: 10 to 85% non-condensing

De LA Rue
NMD 100
Specifications

Media capability- thickness ranges:
Width: 58 to 92mm, Length: 100 to 181mm Thickness: 0.06 to 0.32mm

Maximum note bundle/transaction size- 100 ATM fit banknotes

Maximum cassette capacity-
Short cassette: 240mm or up to 2000 banknotes
Long cassette: 340mm or up to 3000 banknotes

Weight -(without notes)-
Standard 2-denomination NMD 100 (with cassettes) 22.2kg (48.9lbs)

Throat extensions-
85mm, 130mm, 180mm and 320mm

Shutter interface-
The NMD 100 is fitted with an integrated shutter interface.

Communication interface-
RS232C connection standard

Power supply requirement-
120-240V AC 50/60Hz 3A

Operating environment-
Temperature: 5 to 50°C, 41 to 122°F